MTC2 Customized Motor Test Center with 6-50kV up to 8 leads

The MTC2 is a high-end surge voltage tester – no other tester offers such a variety of applications. With the MTC2 precisely analyze coils, stators, armatures, and all other kinds of windings according to the latest technology, without any compromises. Innovations, technical leadership and a patented surge voltage evaluation method characterize the 6th generation of the MTC-2 surge voltage testers. Choose from a finely graded tester variety from 6KV to 50KV. Based on 25 years of experience, extensive know-how and a consistent optimization obtain a state-of-the-art surge voltage tester.

MTC2 Customized

Surge tester with 6-50kV up to 8 leads. A deeper look into the winding – the ultimate surge tester.  No other tester offers so much performance variety.  Reliably test stators, armatures, coils and windings of all kinds.  35 years of pioneering spirit, deep know-how, consistent optimization and permanent R & D activities of our engineers and technicians are the basis for this state-of-the-art surge tester.

Variants - 49 solutions for your testing task.


  • Schleich MTC@ Customized Motor Test Center

    Slide title

    Write your caption here
    Button
  • Slide title

    Write your caption here
    Button
  • Slide title

    Write your caption here
    Button

Winding tests in its purest form.

Intuition – Function – Perfection.

The MTC2 is our premium surge voltage tester – no other tester offers such a diversity of features. With the MTC2 you inspect coils, stators, armatures and all kinds of windings according to the latest state of the art – uncompromising and precise.  Innovations, technology lead and a patented analytical method for surge voltage characterize the MTC2-surge voltage testers of the 6th generation.  A finely graduated variety of testers from 6 kV up to 50 kV  is available.  Based on 25 years experience, extensive know-how and consistent optimization you get THE “state-of-the-art surge voltage tester”.


What makes the MTC2 so special?


4 connection leads offer the possibility to contact all relevant winding connections at the same time. The 3 phase connections and the neutral point are connected to the 4 connection leads.  In this way it is possible to achive a unique test accuracy. 


Automatic test method switch-over - As soon as the test object is connected, the MTC2 automatically measures at all 4 connections. Thanks to the integrated test method switchover, there´s no need for manual re-clamping. This saves time and avoids mistakes.


Advanced surge voltage - The surge voltage test with standard-compliant rise time leaves no defect undetected. Modern, automatic evaluations facilitate the fault analysis.


Optional partial discharge test with surge voltage - The innovative, standard-compliant partial discharge test can easily be integrated. It gives you information about critical insulation weaknesses and the suitability for operation with frequency converters.  SCHLEICH pursues two strategies to obtain good test results at stators as well as at entirely-assembled motors: Measurement via coupler in the measuring lead (perfect for motors) and measurement via antenna (perfect for stators).


Optional precise resistance measurement in 4-wire-technology - To achieve precise measuring results by comparing the three phases´resistances , the resistance is measured in 4-wire technology.  Of course, the 4-wire technolgy is also applied by means of the automatic test method switchover!


Optional high-voltage test with AC - In addition, you can also perform a high-voltage test with AC.  Of course,  the automatic test method switchover is also applicable in this case. 


Optional rotor- / stator test - The measuring technology allows you to find faults in rotors or stators and to detect broken bars in the squirrel-cage rotor.

Winding tests in its purest form.

Class leading equipment features

Inspection of motors and generators up to 500 MW

Surge voltage up to 50 kV

Surge energy 125 Joule

High surge current 2.000 A

Fastest rise time 60 ns

Fully-integrated partial discharge test according to IEC 61934 and DIN EN 60034-18-41

Resistance measurement in 4-wire technology with temperature compensation

Insulation resistance test with automatic PI-measurement

Inductance test| LCR-inductance test bridge

Integrated armature test assistant, armature adapter and armature booster

4 winding connections (windings + neutral point) plus frame connection

A number of tests can be performed without the necessity to reconnect connection leads

Easy and manual inspection without parameterization

Automatic test with subsequent Go/ NoGo – comparison

Result recording with test object-related data

Printing with any Windows-printers plus PDF

Data base for numerous test sequences and test results

Integrated high-quality industrial-PC with Windows®

Full network connectivity

Intuitive operation via touchscreen, mouse and keyboard

Possibility for remote maintenance or remote calibration

Remote control option for automation

Perfect for OEMs

Automation and Interfaces.

  • digital I/O, (input/output 24 V to PLC)
  • RS232 via SCHLEICH communication protocol
  • LAN via SCHLEICH communication protocol
  • LAN via TCP/IP
  • individual special solution …

Benefits of measurement technology at a glance.

Voltage supply


Voltage range 90 – 250 V, 47 – 63Hz

key switch for unlocking

Connections


4 + laminated core (ground)

Autotest


automatic stator-, motor inspection

fully-automatic fault analysis

Surge voltage


6, 12, 15, 25, 30, 40 and 50 kV

automatic and manual surge voltage test

1-, 2- and 3-phase

automatic evaluation

8 different evaluation methods incl. correlation (patented by SCHLEICH)

optional armature booster to inspect DC armatures

High-voltage DC


6, 12, 15, 25, 30, 40 and 50 kV

manually adjustable

automatically programmable

step voltage measurement

Insulation resistance DC


6, 12, 15, 25, 30, 40 and 50 kV

according to VDE 0701

1 MΩ – 100 GΩ

Polarization index


6, 12, 15, 25, 30, 40 and 50 kV

PI-measurement

DAR-measurement

automatic measurement

Partial discharge Surge – Option


6, 12, 15 and 25 kV

according to DIN EN 60034-18:2014

Measurements of

PDIV – Partial discharge inception voltage

RPDIV – Repetitive partial discharge inception voltage

RPDEV – Repetitive partial discharge extinction voltage

PDEV – Partial discharge extinction voltage

Measurements via coupler in the test lead – perfect for motors

Measurements via antenna – perfect for stators

Resistance- Option


1-, 2- and 3-phase

1 mΩ – 100 kΩ

imbalance inspection

4-wire technology

ambient temperature compensation

High-voltage AC – Option


up to 6 kV, 100 mA

1-, 2- and 3-phase

49 to Choose from

Varianten


MTC2 6kV | Test method » Surge

type of tester surge testers

surge test 0–6 kV

insulation all

  0–6 kV ˭

  Vmax like surge test

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

  like surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-HE | Test method » Surge

type of tester surge testers

surge test 0–6 kV

insulation all

  0–6 kV ˭

  Vmax like surge test

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

  like surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3.6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R | Test methods » Surge · R

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R-HE | Test methods » Surge · R

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3.6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R-PD | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 6kV-R-PD-HE | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3,6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 6kV-Rack | Test method » Surge

type of tester surge testers

surge test 0–6 kV

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R-Rack | Test methods » Surge · R

type of tester surge testers

surge test 0–6 kV

resistance all

  4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R-HE-Rack | Test methods » Surge · R

type of tester surge testers

surge test 0–6 kV

resistance all

  4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3.6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-R-PD-Rack | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 6kV-R-PD-HE-Rack | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3.6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 6kV-R-HVAC-Rack | Test methods » Surge · R · HVAC

type of tester surge testers

surge test 0–6 kV

resistance 4-wire measurement

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage AC all

  0–6 kV˜ max. 100 mA

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optinal

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-Caddy | Test method » Surge

type of tester surge testers

surge test 0–6 kV

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 1.8 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 6kV-HE-Caddy | Test method » Surge

type of tester surge testers

surge test 0–6 kV

insulation all

  0–6 kV ˭

polarization index Vmax like surge test

high voltage DC all

  0–6 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 3.6 J

Surge current 800 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —

MTC2 12kV | Test method » Surge

type of tester surge testers

surge test 0–12 kV

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 7.2 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 12kV-HE | Test method » Surge

type of tester surge testers

surge test 0–12 kV

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 14.4 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 12kV-R | Test methods » Surge · R

type of tester surge testers

surge test 0–12 kV

resistance all

  4-wire measurement

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 7.2 J

Surge current 100 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 12kV-R-HE | Test methods » Surge · R

type of tester surge testers

surge test 0–12 kV

resistance all

  4-wire measurement

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 14.4 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 12kV-R-PD | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–12 kV

resistance 4-wire measurement

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 7.2 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 12kV-R-PD-HE | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–12 kV

resistance all

  4-wire measurement

insulation all

  0–12 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

automation 

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 14.4 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 15kV | Test method » Surge

type of tester surge testers

surge test 0–15 kV

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–15 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 11.25 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 15kV-HE | Test method » Surge

type of tester surge testers

surge test 0–15 kV

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–15 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 22.5 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 15kV-R | Test methods » Surge · R

type of tester surge testers

surge test 0–15 kV

resistance all

  4-wire measurement

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–15 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 11.25 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 15kV-R-HE | Test methods » Surge · R

type of tester surge testers

surge test 0–15 kV

resistance all

  4-wire measurement

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–15 kV ˭

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 22.5 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 15kV-R-PD | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–15 kV

resistance all

  4-wire measurement

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–12 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 11.25 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 15kV-R-PD-HE | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–15 kV

resistance all

  4-wire measurement

insulation all

  0–15 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–15 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, Y, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 5 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 200 nF; customer-specific adaptation possible

Surge energy 22.5 J

Surge current 1000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 25kV | Test method » Surge

type of tester surge testers

surge test 0–25 kV

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 25kV-3L | Test method » Surge

type of tester surge testers

surge test 0–25 kV

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switch-over in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 25kV-RF | Test methods » Surge · R

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 25kV-R | Test methods » Surge · R

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 25kV-R-3L | Test methods » Surge · R

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switch-over in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 25kV-RF-PD | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

partial discharge all

  in case of surge test

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 25kV-R-PD | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

partial discharge all

  in case of surge test

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 25kV-R-PD-3L | Test methods » Surge · R · PD

type of tester surge testers

surge test 0–25 kV

resistance all

  4-wire measurement

insulation all

  0–25 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–25 kV ˭

partial discharge all

  in case of surge test

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 4 | automatic switch-over in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 31.25 J

Surge current 1600 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge with microwave antenna

with signal coupling in the test leads


MTC2 30kV | Test method » Surge

type of tester surge testers

surge test 0–30 kV

insulation all

  0–30 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–30 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3| manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 45 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 30kV-3L | Test method » Surge

type of tester surge testers

surge test 0–30 kV

insulation all

  0–30 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–30 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switch over in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 45 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 30kV-RF | Test methods » Surge · R

type of tester surge testers

surge test 0–30 kV

resistance 4-wire measurement

insulation all

  0–30 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–30 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 45 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 30kV-R | Test methods » Surge · R

type of tester surge testers

surge test 0–30 kV

resistance all

  4-wire measurement

insulation all

  0–30 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–30 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 45 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 30kV-R-3L | Test methods » Surge · R

type of tester surge testers

surge test 0–30 kV

resistance all

  4-wire measurement

insulation all

  0–30 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–30 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 45 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 40kV | Test method » Surge

type of tester surge testers

surge test 0–40 kV

insulation all

  0–40 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–40 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 80 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 40kV-3L | Test method » Surge

type of tester surge testers

surge test 0–40 kV

insulation all

  0–40 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–40 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 80 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 40kV-RF | Test methods » Surge · R

type of tester surge testers

surge test 0–40 kV

resistance all

  4-wire measurement

insulation all

  0–40 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–40 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 80 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 40kV-R-3L | Test methods » Surge · R

type of tester surge testers

surge test 0–40 kV

resistance all

  4-wire measurement

insulation all

  0–40 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–40 kV ˭

test terminals T1, T2, T3, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 4 | automatic switchover in the tester

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 80 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 50kV | Test method » Surge

type of tester surge testers

surge test 0–50 kV

insulation all

  0–50 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–50 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the rear

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps —

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 125 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


MTC2 50kV-RF | Test methods » Surge · R

type of tester surge testers

surge test 0–50 kV

resistance all

  4-wire measurement

insulation all

  0–50 kV˭

polarization index Vmax like surge test

high voltage DC all

  0–50 kV ˭

test terminals K1, K2, frame

test cover possible

delivery order-related manufacturing

Test leads pluggable at the front

Number of test leads 3 | manual switchover at the DUT

Housing test lead 1 | stator/motor housing

Kelvin clamps optional

Surge capacitance 100 nF; customer-specific adaptation possible

Surge energy 125 J

Surge current 2000 A; customer-specific adaptation possible

Pulse rise time 100 – 500 ns; according to IEC 60034-18-41

Partial discharge —


Share by: